Version 2.1 – February 2011 130
What dwell times should be used with the LS1 coils sold with my system?
With a 12V charging system.
From idle to approximately 4,000 RPM? Use about 3.0 milliseconds near idle
and no more than about 4.0 milliseconds at approximately 4,000 RPM.
From approximately 4,100 - Max RPM? Use no more than about 6 milliseconds
of total dwell time at max RPM.
With a 16V charging system.
From idle to approximately 4,000 RPM? Use about 2.0 milliseconds near idle
and no more than about 3.0 milliseconds at approximately 4,000 RPM.
From approximately 4,100 - Max RPM? Use no more than about 4.5
milliseconds of total dwell time at max RPM.
For LSx COP engines, make sure the cam sync override box in the “Operating Configuration”
drop down is not
checked.
The Ford Mod Motor COP system must have the “Override Cam Sync Test box, checked.